电气工程学报 ›› 2020, Vol. 15 ›› Issue (4): 138-143.doi: 10.11985/2020.04.017

• • 上一篇    下一篇

扫码分享

分布式多电源开环接线的不同模式的可靠性分析 *

李响1(), 王宝巍2(), 欧阳卫年1, 喻翔2   

  1. 1.广东电网有限责任公司佛山供电局 佛山 528000
    2.北京科锐配电自动化股份有限公司 北京 100193
  • 收稿日期:2020-03-24 修回日期:2020-07-24 出版日期:2020-12-25 发布日期:2020-12-25
  • 作者简介:李响,男,1977年生,高级工程师。主要研究方向为电力系统自动化,智能调度,配网自愈,优化安稳系统等工作的规划与建设。E-mail:yongmudangzzb@163.com
    王宝巍,男,1989年生,硕士,中级工程师。主要研究方向为电力系统自动化,配网自愈。E-mail:yousi96066@163.com
    欧阳卫年,男,1978年生,硕士,高级工程师。主要研究方向为配网调度自动化,变电站自动化,智能调度,配网自愈,电网大数据应用分析等。
    喻翔,男,1989年生,中级工程师。主要研究方向为电力系统自动化,配网自愈。
  • 基金资助:
    * 广东电网有限责任公司科技资助项目(GDKJXM20172911)

Reliability Analysis of Different Modes of Distributed Multi-power Open Loop Wiring

LI Xiang1(), WANG Baowei2(), OUYANG Weinian1, YU Xiang2   

  1. 1. Foshan Power Supply, Guangdong Power Grid Corporation, Foshan 528000
    2. Creative Distribution Automation Co., Ltd., Beijing 100193
  • Received:2020-03-24 Revised:2020-07-24 Online:2020-12-25 Published:2020-12-25

摘要:

为有效协调电网环境中的配置容量,针对不同模式分布式多电源开环接线法的可靠性展开研究。利用多电源滑模控制器协调分布式转矩间的电流比数值,进而计算电动机结构体的开环曲率,完成步进两相混合接线模式设计。重构配电网环境中的所有分布式节点,按照多级优化准则,计算开环馈线量的具体数值,完成双层配网规划接线模式设计。试验分析结果表明,该模式设计适应电网调度能力较强,与“一字”型开环接线法相比,应用步进两相混合接线模式后的电网容量超过100 TW·h,应用双层配网规划接线模式后的电网导容率达到90%,电网环境中的配置容量得到妥善协调,分布式多电源的应用可靠性出现明显上升趋势。

关键词: 分布式电源, 电动机曲率, 配电网重构

Abstract:

In order to coordinate the configuration capacity effectively in the power grid, the reliability of different modes of distributed multi-power source open-loop wiring is studied. The multi-power sliding mode controller is used to coordinate the current ratio between the distributed torques, and then the open-loop curvature of the motor structure is calculated. All the distributed nodes in the distribution network environment are reconstructed, and the specific value of the number of open-loop feeders is calculated according to the multi-stage optimization criteria, and the planning and connection mode design of the double-layer distribution network is completed. The experimental results show that the design of this mode has strong adaptability to power grid dispatching. Compared with the “one word” open-loop connection method, the grid capacity after applying the step-by-step two-phase hybrid connection mode is more than 100 TW·h. After the application of the double-layer distribution network planning and connection mode, the conductivity rate of the power grid can reach 90%, and the configuration capacity in the grid environment is properly coordinated, and the application reliability of distributed multi generation appears an obvious upward trend.

Key words: Distributed power source, motor curvature, distribution network reconfiguration

中图分类号: