Journal of Electrical Engineering ›› 2018, Vol. 13 ›› Issue (9): 32-37.doi: 10.11985/2018.09.006

Previous Articles     Next Articles

Research on Design Method for Average Current Model Control Phase-Shift Full Bridge DC-DC Converter

Ding Qi,Yang Haitao,Liu Cong   

  1. School of Aeronautical Maintenance NCO, Air Force Engineering University Xinyang 464000 China
  • Received:2017-09-24 Online:2018-09-25 Published:2019-11-29

Abstract:

Average current control mode could make phase-shift full bridge dc-dc converter get superior dynamic and static characteristics,but it is difficult to design control parameters for its complicated circuit construction. In the paper, the principle and working process of PS-FB-ZVS converter is expounded in detail, and its small signal model is established, then the average current mode control system’s snall signal mode is build and its transfer function is set up, finally the control parameters are designed. At the end of the paper, simulation and experimental results are given to verify the proposed analysis and design.

Key words: Phase-shift full bridge DC/DC converter, average current mode control, small signal model, parameter design

CLC Number: