摘要:

智能电网技术的发展给高压开关设备智能化提出了新的要求和挑战。本文依据高压开关智能化要求,自监测、自诊断和自控制能力,设计真空断路器智能化过程中触头系统电磨损在线监测装置。该装置触头系统磨损量计算采用改进的开断电流累计加权方法,其中权值的选择和磨损总量的计算依据电寿命曲线采用最小二乘法拟合得到,该法具有通用性,可应用于不同型号的真空断路器;加权积分系数K,采用训练好的LM-BP神经网络,进行动态预测,使K值的选择更加符合工程实际;采用燃弧时间感应器对燃弧时间进行采集,且给出燃弧时间感应器的安装位置和采用的屏蔽措施;硬件处理核心采用TMS320F2812微处理芯片,主要负责算法处理、上位机通信和CAN-BUS控制器局域网通信;短路电流采用罗氏线圈进行采集,且设计电流处理电路,并给出2812AD采样校正办法;最后给出触头系统磨损量在线监测软件流程和设计时应注意的关键技术。

关键词: 真空断路器, 电磨损, 在线监测, 触头系统

Abstract:

Vacuum circuit breakers (VCBs) are widely used in power systems to control and protect power lines and power equipments under the conditions of normal, overload, short circuit and other faults. Once a VCB is unable to interrupt or make a current as designed, especially for the short circuit current, heavy losses would be brought about to both the power system and the consumers. In order to reduce the number of accidents and prevent possible troubles due to the failures of VCBs, one valid way is to monitor their performance and condition on-line. Based on the understanding and development of condition based maintenance (CBM) of high-voltage circuit breakers, the authors give some general introduction to electrical endurance on-line condition monitor for VCBs, in which the stress put on the non-intrusive method and device for determination of the arcing duration. The principle and configuration for arcing duration detect are emphatically expounded in our research, in which the electromagnetic induction theory is adopted for the arcing initialization and duration detect. The simulation and experimental results of the arcing detect device are provided in detail. The accuracy and stability of the arcing detect device have been demonstrated and it can distinguish co-existing arc signals in three-phase of circuit breakers. In the end, an algorithm for the electrical endurance of vacuum circuit breakers on-line condition monitoring system is proposed, which based on TMS320F2812 one type of DSP281X series produced by texas instruments semiconductor. The universally accepted approach of accumulative breaking current of high voltage circuit breaker contact to diagnose electrical endurance is used in the high-voltage circuit breakers electrical endurance on-line monitor system.

Key words: Vacuum circuit-breakers, electrical endurance, on-line monitoring, contact system